Bubble Pressure Tensiometer BP100

 

Print Version    Features     Application     Technical Data     Accessories     Info-Booklet

Tensiometer

K100MK2

K100SF

K100SF with
Autoloader

K11

K9

EasyDyne

K6

PocketDyne

BP100

BP2

DVT30

SITE100

 

Bubble Pressure Tensiometer BP100Printing – bonding – spraying – cleaning:

processes such as these require surfactants that are already effective in fractions of a second – and an instrument that can record their effectiveness. The Bubble Pressure Tensiometer BP100 determines the dynamic surface tension as a function of the surface age. Thus the instrument provides information about wetting and drop formation in rapid processes.

 - Click the photo for a larger view -
Features of the Bubble Pressure Tensiometer BP100
* Measurement of the dynamic surface tension at constant or variable surface age
* Wide range of surface age:
5 ms (high dynamic) up to 100 s (almost static)
* Fully automatic measuring process by software controlled immersion of the capillary
* Determination of the adsorption and diffusion coefficient
* Integrated compressor - no compressed air supply necessary
 
Bubble Pressure Measurement with the BP100

A software-controlled flow of air emerging from a capillary produces air bubbles in the sample. A high-precision pressure sensor determines the maximum pressure during bubble formation, from which the surface tension is calculated. Thanks to its built-in compressor the instrument does not need an external compressed air connection. Thermostatted measurements are possible without any problems.

Scans with an almost unlimited resolution over a wide range of surface ages are controlled automatically by the LabDesk software. In addition to the time-dependent surface tension, the measurement also supplies the equilibrium value according to Hua & Rosen. Diffusion and adsorption coefficients can be calculated from surfactant concentration series – these are important parameters where the mobility of surfactants is concerned. Measurements at constant bubble ages allow further insights, e.g. for concentration or temperature comparisons.

*
After a minimal preparation period the measurement is carried out fully automatically up to data output in the form of a plot. With a mouse-click measuring parameters, results and evaluations appear in a comprehensive report. Thanks to the LabDesk software platform for all KRÜSS tensiometers data from other instruments can be included.
Application
* Surface-active agent development
* Optimization of spraying processes
* Development of detergents and cleansing agents
* Optimization of coating and printing processes
* Electroplating bath concentration control
 
Technical Data of Bubble Pressure Tensiometer BP100
* Measuring range
- SFT (1)
- Temperature

10 - 100 mN/m
-10 to 100 °C
* Resolution
- SFT
- Temperature

± 0.01 mN/m
± 0.01 °
* Surface age (1) 5 ms - 100 s
* Interfaces USB, RS232C
* Power consumption max. 30 W
* Power supply 100 – 240 V AC; 47 – 63 Hz
* Weight 15 kg
* Dimensions 300 x 540 x 320 mm (WxHxL)
(1) : depending on capillary and liquid
 
Measuring Methods
*

Bubble Pressure Method

Measurement of surface tension at constant surface age

Measurement of surface tension at any surface ages from 5 to 100,000 ms

 
Accessories
* Various thermostats
* Capillaries made of glass or PTFE
* Coating Kit to renew the hydrophobicity of the glass capillaries
* Thermostat vessel with built-in magnetic stirrer
 